Sainsbury's – Performance Auditing & Project Management
As part of Reset 6 (Sainsbury’s 20 by 20 Sustainability plan), Energy & Technical Services was appointed to undertake an energy survey of the Dulwich Superstore (47,606 sqft).
Our initial desktop survey from our data scientists identified the store lighting had been on 24/7 after being left in override for 2 years. After deploying a Consultant Engineer to investigate at site, we discovered a number of keys areas where energy savings could be achieved, including operational behavioural issues alongside a number of technical problems.
The existing lighting comprised T8 florescent lights, recess spotlights, down-lighters and florescent tubes in the chilled / frozen cabinets. Much of the cross-shop lighting was below Sainsbury’s lux specifications resulting in dark areas across the sales floor. In addition, the existing controls were inadequate and not achieving lighting levels specifications.
Challenge
Careful consideration was required when proposing suitable dimming controls. Energy & Technical Services worked with client representatives and various stakeholders to ensure the appropriate lighting levels were achieved.
Added Value / Achievements
As a result of our recommendations, the Dulwich store was included in the allocation of the LED lighting programme to resolve the issues highlighted by our consultant. After works were completed, complaints from staff and customers were reduced and the store saw a significant reduction in energy consumption.
Operational behvaiour improved & Technical issue solved
LED lighting programme